The Effect of Dexmedetomidine on Propofol Requirements During Anesthesia Administered by Bispectral Index-Guided Closed-Loop Anesthesia Delivery System: A Randomized Controlled Study

Status: Completed
Location: See location...
Intervention Type: Drug
Study Type: Interventional
Study Phase: Phase 4
SUMMARY

Dexmedetomidine, a selective alpha-2 agonist agent used for maintaining sedation in intensive care patients in receipt of mechanical ventilation, is being increasingly utilized in anaesthesia practice for facilitating anaesthesia depth as an adjunct to base anaesthetics (intravenous; propofol: inhalational; sevoflurane, desflurane). The investigators intend to assess the anaesthetic potential of dexmedetomidine in controlled anaesthesia settings empowered by the use of an objective, patient response based, safe, efficient, and patented closed loop anaesthesia delivery system (CLADS). CLADS functions on control of processed EEG response parameter captured from anaesthetized patients with the help of a BIS- monitor, which is continuously fed into a automated drug infusion pump. The infusion pump then accordingly delivers the anaesthetic drug to the patients based on pharmacodynamic requirements. If dexmedetomidine has anaesthesia potential then it is likely that propofol use delivered by CLADS can be reduced further. In addition the effect of two drugs (viz, base agent-propofol plus adjunct agent-dexmedetomidine) on different receptor site within the brain would help gain greater anaesthetic depth consistency as well as a lower incidence of intraoperative patient awareness. This prospective randomized two-arm study aims to assess effect of the use of dexmedetomidine on propofol requirements (primary objective), anaesthesia depth consistency, and intraoperative patient awareness (secondary objectives).

Eligibility
Participation Requirements
Sex: All
Minimum Age: 20
Maximum Age: 65
Healthy Volunteers: f
View:

• ASA physical status I/II

• Undergoing elective laparoscopic / robotic surgery of more than 60-minutes duration

Locations
Other Locations
India
Sir Ganga Ram Hospital
New Delhi
Time Frame
Start Date: 2015-12-05
Completion Date: 2017-03-20
Participants
Target number of participants: 80
Treatments
Active_comparator: Dexmedetomidine group
Patients will receive a pre-induction loading dose of dexmedetomidine 1-µ/kg over 10 minutes followed by an intraoperative infusion of 0.5-µ/kg/hour . Over and above the use of study drug dexmedetomidine propofol administration will be controlled with Closed Loop Anaesthesia Delivery system to maintain a consistent anaesthetic depth (BIS 40-60) using bispectral index monitor in all the patients
Placebo_comparator: Non-Dexmedetomidine group
Patients will receive a pre-induction loading dose of 0.9% saline solution over 10 minutes followed by an intraoperative infusion.Over and above the use of 0.9% saline solution propofol administration will be controlled with Closed Loop Anaesthesia Delivery system to maintain a consistent anaesthetic depth (BIS 40-60) using bispectral index monitor in all the patients